Skip to content
RRB Security
EN
MenuClose

EN 54 certified, according to AJAX

EN 54 fire alarm system with AJAX

An EN 54 fire alarm system with AJAX technology provides wireless fire detection and alarm signalling for commercial premises. The detectors and sounders work together with a control panel, so alerts are displayed clearly.

RRB Security takes care of the advice, design, installation and maintenance. We tailor the solution to your premises, how they are used and the applicable requirements. If required, we provide signal transmission to an alarm receiving centre (ARC).

Security specialist since 1995

EN 54 fire alarm system with AJAX fire alarm control panel and wireless detectors

31years of experience

  • EN 54Certified, according to AJAX
  • WirelessLess cabling needed
  • 200Devices per control panel
  • ARCDirect signal transmission

From advice to maintenance

Everything for your AJAX EN54 fire alarm system

One dedicated specialist, an open quote and a solution that fits your location, organisation and security needs.

  1. Advice and design

    We assess your premises, determine which detectors are needed and where, and draw up a layout of fire zones. You receive a well-founded proposal.

  2. Installation

    Thanks to the wireless connections, considerably less cabling is needed and installation is much faster than with a wired system. This keeps disruption to a minimum, including in occupied premises and listed buildings.

  3. Remote maintenance

    We monitor the technical status of the system and support its management remotely. We plan maintenance and any other work around the situation and use of your premises.

  4. Signal transmission

    If required, we set up the link to an ARC to receive fire and fault alerts. The connections and follow-up are set up in line with the agreements made.

Trusted across the Benelux

These organisations trust our solutions

Personal advice

Want better security for your organisation?

Discuss your requirements with one of our specialists, with no obligation.

EN 54 fire alarm system from AJAX: EN54 Fire Hub fire alarm control panel with touchscreen

31years of experience

Fire alarm and security specialist

Why do clients choose RRB Security?

Since 1995, RRB Security has provided security solutions for businesses, government bodies and institutions. As an AJAX Integrator, we support you from advice and design to installation and maintenance. We also look at the options for combining fire detection with other security systems.

  • One point of contact from design to maintenance
  • AJAX Integrator
  • Fire, intruder alarm and CCTV in one system
  • Remote maintenance and fault handling

Components

What are the components of the AJAX EN54 fire alarm system?

The system consists of a fire alarm control panel, detectors and components for alarm signalling and management. We select the right components based on your premises and the intended use. Below you will find an explanation and the technical specifications for each component.

Control panel, range and management

EN 54 fire alarm system from AJAX: EN54 Fire Hub fire alarm control panel

EN54 Fire Hub

The fire alarm control panel is the central point of the system. The touchscreen gives an overview of alerts, faults and the status of the connected devices.

Specifications
  • According to AJAX: EN 54-2, -4, -13, -21 and -25
  • Up to 200 devices, 40 zones
  • Mains power with backup battery for up to 24 or 72 hours
  • Range up to 1,800 m
EN 54 fire alarm system from AJAX: EN54 Fire ReX range extender

EN54 Fire ReX

A range extender increases the wireless range within your premises. It can be used when the size or construction of the building calls for extra support for the connections.

Specifications
  • According to AJAX: EN 54-4, -18 and -25
  • Up to 5 per control panel
  • Mains power with backup battery for up to 100 hours
EN 54 fire alarm system from AJAX: management via AJAX PRO Desktop

AJAX PRO Desktop and apps

We use AJAX's software to support management and maintenance remotely. The app gives you insight into the status and alerts of your system.

Detectors

EN 54 fire alarm system from AJAX: EN54 FireProtect smoke detector

Smoke detector

Detects smoke and reports it to the fire alarm control panel. The choice and positioning are matched to how the room is used. Also available with a built-in sounder.

Specifications
  • According to AJAX: EN 54-7 and -25 (with sounder also EN 54-3)
  • Battery life up to 6 years (with sounder up to 5 years)
  • Mounting without opening the housing
EN 54 fire alarm system from AJAX: EN54 FireProtect heat detector (black)

Heat detector

Detects temperature changes that may indicate a fire. A possible solution for rooms where smoke detection is less suitable, such as kitchens. Also available with a built-in sounder.

Specifications
  • According to AJAX: EN 54-5
  • Battery life up to 6 years (with sounder up to 5 years)
  • Classes A1 to CS
EN 54 fire alarm system from AJAX: EN54 FireProtect heat and smoke detector

Heat and smoke detector

Combines smoke and heat detection in one detector. The settings are matched to the conditions and use of the room.

Specifications
  • According to AJAX: EN 54-5, -7, -25 and -29
  • Battery life up to 6 years

Alarm signalling

EN 54 fire alarm system from AJAX: EN54 FireProtect sounder

Sounder

Gives an audible alarm signal when fire is detected. The positioning and settings are matched to the layout and use of the premises.

Specifications
  • According to AJAX: EN 54-3 and -25
  • Battery life up to 5 years
  • IP54
EN 54 fire alarm system from AJAX: EN54 FireProtect sounder with beacon

Beacon and sounder with beacon

Gives a visual alarm signal in addition to the audible alarm, for example in rooms with a lot of background noise. Available as a separate beacon or combined with a sounder.

Specifications
  • According to AJAX: compliant with EN 54-23, and with EN 54-3 when used with a sounder
  • Battery life up to 5 years
  • IP54
EN 54 fire alarm system from AJAX: AJAX Indicator alarm light

Indicator

Shows outside a room that a linked detector has raised an alarm. This helps to locate an alert, for example when a detector is hard to see.

Specifications
  • Battery life up to 5 years
  • IP54

Manual activation and integration

EN 54 fire alarm system from AJAX: red ManualCallPoint manual call point

Manual call point

Allows anyone who discovers a fire to raise the alarm manually. The location of the alert is visible in the system.

Specifications
  • Red version, according to AJAX: EN 54-11 and -25
  • Battery life up to 7 years
EN 54 fire alarm system from AJAX: EN54 I/O Module (2X2)

I/O module

Enables integration with other installations, for example to control doors or ventilation. The application is matched to the layout of the premises.

Specifications
  • According to AJAX: EN 54-18 and -25
  • Battery life up to 5 years

Video

The AJAX EN54 fire alarm system on video

This video from AJAX gives an overview of the EN54 line and how the system works.

Applications

Which buildings is the AJAX EN54 fire alarm system suitable for?

Offices

Fire detection tailored to the layout, occupancy and use of your office.

Shops

A wireless system that can be adapted when the layout or use of the shop changes.

Hospitality and hotels

Detection and alarm signalling tailored to the different functions within the premises, from kitchen to guest rooms.

Warehouses and industry

A design that takes account of the size, construction and conditions within the premises.

Education

Fire detection tailored to classrooms, shared facilities and daily occupancy.

Museums and heritage

Wireless connections reduce the cabling needed and help the system fit sensitively into the building.

Advice

What should you look for in a fire alarm system?

The right fire alarm system starts with an assessment of your premises and the applicable requirements. We include the topics below in our advice.

When should you choose EN 54?

EN 54 is the European series of standards for components of fire detection and fire alarm systems. According to AJAX, the control panel and the components of the EN54 line meet these standards. For commercial buildings, that is an important difference from consumer detectors, which are not tested against that standard.

Mandatory fire alarm system and NEN 2535

If a fire alarm system is mandatory for your building, for example under the environmental permit (omgevingsvergunning) or the Dutch Building Works (Living Environment) Decree (Besluit bouwwerken leefomgeving), the Netherlands requires compliance with NEN 2535, the Dutch standard for fire alarm systems, and often certification. This is assessed per building. Together with you, we look at whether the AJAX EN54 fire alarm system suits your situation, or which route is needed.

Wireless or wired

Wireless connections reduce cabling work and allow faster installation. We assess which version suits your premises and take any future extensions into account.

Range and range extenders

We assess the wireless range within your premises. Where the size or construction calls for it, we include range extenders in the design.

Batteries and maintenance

The system monitors the battery status and operation of the detectors. We plan checks and replacements based on the alerts, the usage and the maintenance needs.

Signal transmission to the ARC

A link to an ARC means fire and fault alerts are received and followed up. We advise on the connections and record the required follow-up in agreements.

Fire zones and evacuation

Dividing the building into fire zones helps to identify where an alert comes from. We match the audible and visual alarm signalling to the premises and the evacuation arrangements.

Integration with intruder alarms and CCTV

The AJAX platform lets you manage fire detection, intruder alarms and camera footage together. We advise on the combination that suits your situation. Read more on AJAX alarm system and Camera security.

Frequently asked questions

Frequently asked questions about the AJAX EN54 fire alarm system

Can't find your question? Our specialists are happy to help with advice that fits your situation.

What is the difference between the AJAX EN54 line and the AJAX FireProtect 2?

The FireProtect 2 is designed for smoke and heat detection within an AJAX alarm system for homes. The EN54 line is a fire alarm system for commercial premises, with its own control panel and components that, according to AJAX, meet the EN 54 standards. We advise on the solution that suits your situation.

Is the AJAX EN54 fire alarm system wireless?

The detectors and sounders communicate wirelessly and run on batteries. The control panel and any range extenders need mains power and have a backup battery.

How many detectors can I connect?

One EN54 Fire Hub supports up to 200 devices, spread over 40 fire zones.

How long do the batteries last?

Battery life varies by component and usage. The system alerts you when a replacement is needed. The product specifications give an indication of battery life.

Can the system transmit alerts to an ARC?

Yes, the system can be linked to an alarm receiving centre. We tailor the connections and the follow-up of alerts to your situation.

Can I extend the system with intruder alarms and CCTV?

The AJAX platform offers ways to combine these functions. We assess which extension fits your premises and your existing security.

Personal advice

Contact form

Tell us briefly what your request is about. We will contact you personally.

  • No-obligation advice and quote
  • Quick response from a specialist
  • Specialised in security technology

No-obligation quote

Personal advice from a specialist

We will contact you as soon as possible.

Interested in

Prefer to call? 085 303 48 69